Stackable Series


|
MODEL ES5.12 |
|
|
Rated Voltage |
51.2Vdc |
|
Number of battery strings |
16strings |
|
Rated Capacity |
100Ah |
|
Rated Energy |
5120Wh |
|
Number of parallel machines |
15parallel |
|
Cell Type |
LiFePO4 |
|
Charge and discharge parameters |
|
|
Over-charge Protection Voltage |
58.4Vdc |
|
Over-discharge Protection Voltage |
43.2Vdc |
|
Rated Charge Current@RT |
50A |
|
Max Charge Current@RT |
100A |
|
Over Charge Protection Release |
Discharge/ Voltage recovery |
|
Operating Temp Range |
discharge(·20-55°C), charge(0-55℃) |
|
Output Voltage Range |
43.2-58Vdc |
|
Rated Discharge Current @RT |
100A |
|
Max Discharge Current@RT |
105A |
|
Over Discharge Protection Release |
Charging/ Voltage recovery |
|
Battery protection parameters |
|
|
Over-charge protection |
3700mV@ ls |
|
Over-charge protection release |
3380mV |
|
Over-charge release method |
Cell 3380mV or Discharge |
|
Over-discharge protection |
2800mV@5s |
|
Over-discharge protection release |
2700mV |
|
Over-discharge release method |
Cell 2950mV or Charging |
|
Over current protection(CHG) |
110A@1s/210A@3s |
|
Over current protection(DISCHG) |
150A@20ms/210A@3ms |
|
Over current release method (CHG) |
Remove the charger |
|
Over current release method (DISCHG |
) Cut off loads |
|
Over temperature |
Protaction@70℃/ Protaction Release@50℃ |
|
Over temperature |
Protaction @85'C/ Protaction Release@64℃ |
|
Parameters |
|
|
Communication |
CAN/RS485 |
|
IP level |
IP30 |
|
Operating Temperature Range |
discharge(-20-55°C), charge(0-55°C) |
|
Storage Temperature |
-15℃ to 60℃ |
|
Standard Configuration |
PVinput line speed(1m) |
|
Dimension(unit) L*W*H(mm) |
635*480*180 |
|
Weight(N. W.) |
48kgs |
|
Models SIF6000-24812H SIF11K-24816H |
||
|
Rated load power |
6000W |
11000W |
|
Parallel Function |
≤12 units in parallel.Parallel output380AC |
Paraction |
|
MAX PV Array Power |
6500W |
5500W*2=11KW |
|
MPPT input interface |
2way |
|
|
Battery rated voltage |
48VDC |
48VDC |
|
Lithium battery activation |
Mains& Photovoltaic charging activation |
|
|
AC INPUT |
||
|
Voltage |
230VAC |
|
|
Selectable Voltage Range |
170-280VAC(PC)/90-280VAC (HomeAppliances) |
|
|
Frequency Range |
50Hz/60Hz(Auto detection) |
|
|
AC OUTPUT |
||
|
AC Voltage Regulation (Batt. Mode) |
230VAC±5% |
|
|
Surge power |
12000W |
22000W |
|
Transfer Time |
10ms (PC) /20ms (Home Appliances) |
|
|
BATTERY &AC CHARGER |
||
|
Battery Voltage |
48VDC |
48VDC |
|
Floating Charge Voltage |
54VDC |
54VDC |
|
Overcharge Protection |
61VDC |
61VDC |
|
Maximum charge current |
80A |
120A |
|
SOLAR CHARGER |
||
|
MAX PV Array Power |
6500W |
5500W*2=11KW |
|
MPPT Range@ Operating Voltage |
55-450VDC |
|
|
Maximum PV Array Open Circuit Volta |
ge 450VDC |
|
|
Maximum Charging Current |
120A |
160A |
|
Maximum Efficiency |
99% |
|
|
Parameter |
||
|
Communication |
RS485 |
|
|
IP level |
IP20 |
|
|
Certificate |
CE |
|
|
Operating Temperature |
-10℃to55℃ |
|
|
Storage Temperature |
-15℃to60℃ |
|
|
Dimension. D*WH(mm) |
450*300*130 |
|
|
NetWeight(kgs) |
9.6 |
|
|
Optional Configuration |
WIFI module |
|
♦ The ES series stackable lithium batteries are new products developed for household energy storage systems.
♦They feature integration, miniaturization, lightweight, intelligence and standardization.
♦The batteries have high safety and a long service life, and are widely used in fields such as indoor distribution
stations,integrated base stations, household photovoltaic energy storage, and distributed power supply.